Efficiency of Heat Loss Reduction in the Intermediate Ladle PDF Full text

 

A. N. Smirnov1, A. L. Podkorytov2, M. V. Yepishev3

1 Donetsk National Technical University
58 Artema St., 83001, Donetsk, Ukraine
2 OJSC “Yenakiyevskiy Iron & Steel Works”
9 Metallurgov Ave., Yenakievo, Donetsk region, 86400, Ukraine
3 Pryazovskiy State Technical University
7 Universitetskaya St., Mariupol, 87500, Ukraine

UDC 669.18.046.518

Metall. Min. Ind.2010, Vol. 2, No. 4, pp. 308-313

Abstract

Data on temperature conductivity coefficient measurement of three grades of rice husk ash and synthetic heat-insulating mixture are presented. Results of steel temperature measurement in the intermediate ladle of 6-strand continuous-casting machine when casting under rice husk ash and synthetic heat-insulating mixture are compared. Rice husk ash showed the best heatinsulating ability.

Keywords: CONTINUOUS-CASTING MACHINE, HEAT-INSULATING MIXTURE, STEEL POURING, HEAT LOSS, INTERMEDIATE LADLE

  